NORDAC SK 200E Manual
120
Subject to technical alterations BU
0200
GB
Display
Error
Cause
¾
Remedy
Identification errors
220
UNKNOWN DEVICE
Device ID not found. The connected inverter is not listed in the database of
the ParameterBox; no communication can be established.
¾
ParameterBox is too old for the FI.
¾
Please contact your Getriebebau Nord Representative.
221
SOFTWARE VERSION
NOT RECOGNISED
The software version was not found. The software of the connected
frequency inverter is not listed in the ParameterBox database, no
communication can be established.
¾
Please contact your Getriebebau Nord Representative.
222
CONFIGURATION STAGE NOT
RECOGNISED
An unknown component has been detected in the frequency inverter
(Customer interface).
¾
Please check the components installed in the frequency inverter
¾
If necessary, check the software version of the ParameterBox and the
frequency inverter.
223
BUS CONFIGURATION HAS
CHANGED
After restoring the last Bus configuration, a device is reported that is different
from the one stored. This error can only occur if the parameter >Auto. Bus
Scan< is set to OFF and another device has been connected to the
ParameterBox.
¾
Activate the Automatic Bus Scan function.
224
DEVICE NOT SUPPORTED
The inverter type entered in the ParameterBox is not supported!
¾
The ParameterBox cannot be used with this inverter.
225
THE CONNECTION TO THE
INVERTER IS BLOCKED
Access to a device that is not online (previously Time Out error).
¾
Carry out a bus scan via the parameter >Bus Scan< (P1001).
ParameterBox operating error
226
SOURCE AND TARGET ARE
DIFFERENT DEVICES
Copying objects of different types (from / to different inverters) is not
possible.
227
SOURCE IS EMPTY
Copying of data from a deleted (empty) storage medium
228
THIS COMBINATION IS NOT
PERMITTED
Target and source for the copying function are the same. The command
cannot be executed.
229
THE SELECTED ITEM IS EMPTY
Parameterisation attempt of a deleted storage medium
230
DIFFERENT SOFTWARE VERSIONS
Warning:
Copying objects with different software versions can cause problems when
transferring parameters.
231
INVALID PASSWORD
Attempt to alter a parameter without a valid Box password being entered in
parameter >Box Password< P 1306.
232
BUS SCAN ONLY WHEN IN MODE:
ONLINE
A bus scan (search for a connected frequency inverter) is only possible when
in ONLINE mode.
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...