3 Options
BU 0200 GB
Subject to technical alterations
93
Example for the connection of SK TU4-PBR to SK 200E
NOTE
Looping of the 24V supply voltage
(terminals 11/15)
is in principle possible, however, a
maximum current load of
3A
for the
SK TU4-PBR(-…)
must not be exceeded!
Detail of the M12 connections of the SK TU4-PBR-M12
The special wiring of the M12 round plug connectors enables the connection of both single and double
sensors, which are equipped with normal M12 system plugs with standard sensor/actuator wiring.
If the M12 round plug connectors
are used, the terminal block
connections for the digital inputs
(terminals 19, 20, 25, 26) must
not be used.
SK 205E…-Connection unit (SK TI4…)
SK TU4-PBR…-Connection unit (SK TI4-TU-BUS)
Voltage
Source
24V DC
PROFIBUS
Subscriber
X-1
PROFIBUS
Subscriber
X+1
Wiring of the M12-plug
connector to
SK TU4-…-M12
(Power/C