4 Display and control
BU 0200 GB
Subject to technical alterations
111
4.1.2
ParameterBox SK PAR-3H
This option is for simple parameterisation and control of the frequency inverter, as well as the display of current
operating settings and states.
Up to 5 FI data sets can be stored and managed, stored and transferred with this device. This enables an
efficient commissioning for serial applications.
Features of the ParameterBox
•
Illuminated, high resolution LCD graphics screen
•
Large-screen display of individual operating
parameters
•
6 language display
•
Help text for error diagnosis
•
5 complete inverter data sets can be stored in the
memory, loaded and processed
•
Can be used for the simultaneous display of several operating values
•
Standardisation of individual operating parameters to display specific system data
•
Direct control of a frequency inverter
Information from the ParameterBox
After plugging the ParameterBox onto the frequency inverter and switching on the mains for the first time,
there is initially an enquiry as to the menu language, German or English. The required language is
confirmed by pressing OK.
Then the ParameterBox automatically carried out a
“bus scan”
, during which the connected frequency
inverters are identified.
In the following display, the type of frequency inverter, its actual operating condition and the current status
can be seen.
After the inverter has been enabled, the display mode changes to the 3 current operation values (frequency,
voltage, current). The operating values displayed can be selected from a list of possible values (in the
>Display< / > Values< menu).
NOTE
The digital frequency setpoint (Jog frequency/minimum frequency) has a default setting of
0Hz. To check whether the motor is working, a frequency setpoint must be entered with the
key or a jog frequency entered via the relevant menu level >Parameterise<, >Base
parameters< and the relevant parameter >Jog frequency< (P113)..
Settings should only be made by qualified personnel, in strict compliance with the warning
and safety information.
ATTENTION:
The motor may start immediately after pressing the START key
!
ATTENTION
With the use of a ParameterBox SK PAR-3H this must never be simultaneously connected to
the frequency inverter and the PC, as potential shifts may cause damage, especially to the
PC. (See also Manual BU0040)
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...