6 Parameterisation
BU 0200 GB
Subject to technical alterations
197
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P750 Over
current
statistic
S
0 ... 9999
Number of overcurrent messages during the operating period P714.
P751 Over
voltage
statistic
S
0 ... 9999
Number of overvoltage messages during the operating period P714.
P752 Mains
fault
statistic
S
0 ... 9999
Number of mains faults during the operating period P714.
P753 Over
temperature
statistic
S
0 ... 9999
Number of overtemperature faults during the operating period P714.
P754 Parameter
loss
statistic
S
0 ... 9999
Number of parameters lost during the operating period P714.
P755 System
error
statistic
S
0 ... 9999
Number of system faults during the operating period P714.
P756 Time
out
statistic
S
0 ... 9999
Number of Time out errors during the operating period P714.
P757 Customer
error
statistic
S
0 ... 9999
Number of Customer Watchdog faults during the operating period P714.
P760 Actual
mains
current
S
0.0 ... 50
Displays the actual input current.
P799
[-01]
...
[-05]
Operating hours last error
(or duration of error)
0.00 ... ___ h
This parameter shows the operating hours counter status (P714) at the moment of the previous
fault. Array [-01] ... [-05] corresponds to the last fault 1 ... 5.
Summary of Contents for SK 200E Series
Page 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Page 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Page 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Page 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Page 263: ...10 Keyword index BU 0200 GB 263...
Page 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Page 265: ...The Nordac SK 200E is available to order from www inverterdrive com...