4 - 6
4.5.4
Setting OxyCRG Parameters
Select parameter trends or compressed waveform to set parameters and the compressed waveform you want to
display. The selected parameters will be used for ABD event calculation.
4.5.5
Setting the Threshold of ABD Events
Select any parameter trend or the compressed waveform to perform the following setup:
■
Set the threshold of ABD events.
■
Set
Event Storage Format
:
◆
1 min+3 min
: stores data one minute before and three minutes after the event.
◆
3 min+1 min
: stores data three minutes before and one minute after the event.
◆
2 min+2 min
: stores data two minutes before and two minutes after the event.
The stored data includes the trends of the OxyCRG parameters, compressed waveform, alarm thresholds, NIBP,
and Temp measurements.
4.5.6
Editing ABD Events
To edit ABD events, follow this procedure:
1.
Select the
Mark
button to enter the
Mark
dialog box.
2.
Drag the event list upwards and downwards to select the desired event.
3.
Select the patient’s status when the event happens.
4.
Select
Save
.
4.6
The Targeted Goal Screen
If you are concerned with specific parameters and their trends, you can use the Targeted Goal screen. The
Targeted Goal screen focuses on the target parameter and displays parameter measurements in big numerics.
You can easily identify whether parameter target is reached via a dashboard and review the statistics of the
target parameter by sections.
The Targeted Goal screen displays parameter measurements and waveforms of ECG, SpO
2
, IBP, PI, PR, CO
2
, Resp,
NIBP, and Temp. You can define the target parameter and secondary parameters. The measurements of these
parameters displays in big numerics.
4.6.1
Entering the Targeted Goal Screen
To enter the Targeted Goal screen, choose any of the following ways:
■
Select the
Screen Setup
quick key
→
select the
Choose Screen
tab
→
select
Targeted Goal
.
■
Select the
Main Menu
quick key
→
from the
Display
column select
Choose Screen
→
select
Targeted
Goal
.
■
If the
Patient Category
is set to
Neo
, swipe left or right on the touchscreen with two fingers to switch to
the Targeted Goal screen.
Summary of Contents for ePM 10M
Page 1: ...ePM 10M ePM 10MA ePM 10MC ePM 12M ePM 12MA ePM 12MC Patient Monitor Operator s Manual ...
Page 2: ......
Page 58: ...4 8 This page intentionally left blank ...
Page 62: ...5 4 This page intentionally left blank ...
Page 118: ...11 4 This page intentionally left blank ...
Page 134: ...13 12 This page intentionally left blank ...
Page 144: ...15 8 This page intentionally left blank ...
Page 156: ...16 12 This page intentionally left blank ...
Page 174: ...18 12 This page intentionally left blank ...
Page 182: ...19 8 This page intentionally left blank ...
Page 192: ...20 10 This page intentionally left blank ...
Page 222: ...24 4 This page intentionally left blank ...
Page 228: ...25 6 This page intentionally left blank ...
Page 256: ...28 6 This page intentionally left blank ...
Page 264: ...29 8 This page intentionally left blank ...
Page 268: ...30 4 This page intentionally left blank ...
Page 280: ...31 12 This page intentionally left blank ...
Page 346: ...E 4 This page intentionally left blank ...
Page 350: ...F 4 This page intentionally left blank ...
Page 360: ...G 10 This page intentionally left blank ...
Page 361: ...H 1 H Declaration of Conformity ...
Page 362: ...H 2 This page intentionally left blank ...
Page 363: ......
Page 364: ...P N 046 012607 00 6 0 ...