- 5.6 -
10. Set the doctor on the front side to remove
adhesive.
Set the doctor between the front cover and peeling roller. Tighten
the mounting screw securely.
11. Press [ENTER] key, then rolling the belt.
Press [ ] and [ ] key to send out the belt while
adjusting the belt speed up to about 30mm/s.
12. Drop kerosene or diesel on the backside of the
doctor until it sinks sufficiently into adhesive
on the belt surface.
• If kerosene or diesel is applied too much,
when removing the adhesive, extra kero-
sene or diesel leak out the side of doctor
and drop into the Cleaning liquid tank unit
through the belt. If kerosene or diesel mixed
with cleaning liquid, it declines the adhesive
force when printing with belt cleaning.
Therefore if adhesive force suddenly
declined after the adhesive replacement,
there is a possibility of kerosene or diesel
mixed into cleaning liquid.
Confirm the cleaning liquid every time after
removing the adhesive or applying the
kerosene or diesel. If kerosene or diesel is
mixed, clean the belt with reference to the
maintenance menu "Belt Cleaning" (P3.32)
To perform the belt cleaning, put a little
amount of mild detergent into the cleaning
liquid tank and rotate the belt. After that,
change the water in the cleaning liquid tank
to the new one.
Belt Maintenance
Start
: ent
Stop < END > Key
Speed = 1 0 mm / s
Stop < END > Key
Speed = 3 0 mm / s
Doctor