- 4.26 -
10. Press [ENTER] key.
11. Select the tolerance level for the missing shot
dots by pressing JOG key [ ] and [ ].
The good or bad range of the ink adherent position is set at level 0
to level 2. In case the setting judges the position as NG, this NG is
added to Total NG at procedure 5.
In case nozzle clogging has detected or number of missing shot
dots exceed the setting value that was set at the step 9 as a
tolerance level, plotter stop the operating and execute the nozzle
cleaning.
The illustration in the right is an example of 10 nozzle clogging
has detected when tolerance level is set to "level 1".
At this time, "MissShot NG" is set to 25. Therefore plotter does
not stop the operation or execute the nozzle cleaning
• Measures should be changed according
to the settings in the step 9 of the “ANRS
Setup” (Refer to Page P.4.21)
11. Press [ENTER] key.
12. Press [END] key twice, and the menu returns
to the LOCAL mode.
TYPE1
ANRS Ctrl
< ent >
<< LOCAL >>
width : 1620mm
TYPE1
MissShot NG
= 0
TYPE1
MissShot NG
= 25
=
0
=
10
Missing
position
*In case of setting value is 25