MMUART Peripherals
UG0331 User Guide Revision 15.0
500
13.4.13 Scratch Register (SR)
13.4.14 Multi-Mode Control Register 0 (MM0)
1
DDSR
R
0
Delta data set ready (DDSR) indicator. Indicates that the DSRn input has
changed state since the last time it was read by the Cortex-M3 processor.
Whenever bit 0, 1, 2, or 3 is set to 1, a modem status interrupt is
generated.
0
DCTS
R
0
Delta clear to send (DCTS) indicator. Indicates that the CTSn input has
changed state since the last time it was read by the Cortex-M3 processor.
Whenever bit 0, 1, 2, or 3 is set to 1, a modem status interrupt is
generated.
Table 484 •
SR
Bit
Number
Name
R/W
Reset
Value
Description
[7:0]
SCR
R/W
0
Scratch register. This register has no effect on MMUART_x operation.
Table 485 •
MM0
Bit
Number
Name
R/W
Default
State
Description
7
EFBR
R/W
0
Enable fractional baud rate (FBR) mode.
0: Disabled (default)
1: Enabled
6
ERTO
R/W
0
Enable receiver timeout (RTO). Writing this bit enables the timeout and
restarts the counter value. The timeout value is determined by the
register.
0: Disabled (default)
1: Enabled
5
ETTG
R/W
0
Enable transmitter time guard (TTG). The time guard value is determined
by the
Register.
0: Disabled (default)
1: Enabled
4
Reserved
R/W
0
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read- modify-write operation
3
ELIN
R/W
0
Enable LIN header detection and automatic baud rate calculation.
0: Disabled (default)
1: Enabled
[2:0]
ESYN
R/W
0
Enable synchronous operation. There are four types of Synchronous
Operation modes that can be enabled.
0b000: Disabled, that is, Asynchronous mode (default)
0b001: Synchronous slave enabled, positive-edge clock
0b010: Synchronous slave enabled, negative-edge clock
0b011: Synchronous master enabled, positive-edge clock
0b100: Synchronous master enabled, negative-edge clock
0b101, 0b110, and 0b111: Reserved
Table 483 •
MSR
(continued)
Bit
Number
Name
R/W
Reset
Value
Description