215184
481
Revision A
1016049
A
Figure 9.390: New Holland Combine Display
1.
On the main page of the combine display, select
DIAGNOSTICS (A). The DIAGNOSTICS page opens.
1024227
A
B
C
Figure 9.391: New Holland Combine Display
2.
Select SETTINGS tab (A). The SETTINGS page opens.
3.
From GROUP menu (B), select HEADER.
4.
From PARAMETER menu (C), select REEL VERTICAL
POSITION.
1023921
A
B
C
Figure 9.392: New Holland Combine Display
5.
Select GRAPH tab (A). The REEL VERTICAL POSITION graph
displays.
6.
Lower the reel to view high voltage (B). The voltage should
be 4.1
–
4.5 V.
7.
Raise the reel to view low voltage (C). The voltage should
be 0.5
–
0.9 V.
8.
If either voltage is out of range, refer to
Adjusting Reel Height Sensor, page 487
.