215184
367
Revision A
1003782
Figure 9.138: CLAAS Combine Display
5.
Use the < or > key to select CUTT. HEIGHT LIMITS, and press
the combine controls OK key.
6.
Follow the procedure displayed on the screen to program
the upper and lower limits of the header into the CEBIS.
1003783
Figure 9.139: CLAAS Combine Display
7.
Use the
<
or
>
key to select SENSITIVITY CAC, and press the
combine controls OK key.
NOTE:
Setting the sensitivity of the AHHC system affects the
reaction speed of the AHHC on the header.
8.
Use the
–
key or the
+
key to change the setting of the
reaction speed, and press the combine controls OK key.
1003784
A
B
Figure 9.140: CLAAS Combine Display
9.
Use line (A) or value (B) to determine the sensitivity setting.
NOTE:
The setting can be adjusted from 0
–
100%. When sensitivity
is adjusted to 0%, the signals from the sensing bands have
no effect on the automatic cutting height adjustment.
When sensitivity is adjusted to 100%, the signals from the
sensing bands have maximum effect on the automatic
cutting height adjustment. The recommended starting point
is 50%.
NOTE:
If float was set heavier to complete the AHHC calibration
procedure, adjust to recommended operating float after
the calibration is complete.