215184
330
Revision A
1018435
A
B
C
D
E
F
G
Figure 9.50: Header Groups
1.
To view header group settings, touch HEADER icon (A) on
the right side of the home page.
2.
The following information is displayed:
•
CURRENT POSITION of header (B).
•
SETPOINT cut-off position (C) (indicated by red line)
•
HEADER symbol (D)
–
touch to adjust the setpoint cut-
off position using the adjustment wheel on the right
side of the Tyton terminal.
•
CUT HEIGHT for AHHC (E)
–
fine-tune with the header
height setpoint control dial on the header control
cluster.
•
HEADER WORKING WIDTH (F)
•
HEADER PITCH (G)
1018476
A
Figure 9.51: Adjustment Wheel on Right of Tyton
Terminal
3.
Touching a field opens the on-screen keyboard so that
values can be adjusted. Enter the new value and touch the
green check mark when complete.
NOTE:
Adjustment wheel (A) is located on the right of the Tyton
terminal.
1027730
A
Figure 9.52: Header Control Cluster
NOTE:
HEADER HEIGHT SETPOINT control dial (A) is on the header
control cluster.