Figure 9.212: Combine Heads-Up Display
1003626
A
B
C
D
E
F
NOTE:
Displayed on LCD (A) as XX in. or XXX cm.
Alarm conditions:
If an error message is received from the fuse panel, an audible alarm sounds. The alarm buzzer sounds five times every 10
seconds. The LCD on the electronic instrument panel (EIP) indicates the header system in error as HDR CTRL followed by
HGT ERR for height, and HDR CTRL followed by TILT ERR for tilt. The header height LED flashes yellow two times every
second.
When an alarm condition occurs, a green LED flashes on and off (green, yellow, or red depending on the input). In addition,
a message is displayed on the LCD to identify the nature of the alarm. For example, HYD TEMP, OPEN, SHRT will be flashed
alternately.
Diagnostic fault failures:
Refer to Figure
Pressing header height switch (B) for a minimum of 5 seconds will put the EIP in header diagnostic mode. The LCD (shown
on previous screen) will display the message HDR DIAG when the EIP has entered header diagnostic mode.
In this mode, after 3 seconds, header fault parameter labels are displayed on the EIP LCD. All the information displayed is
read-only.
OK (C) and CLEAR (D) buttons allow you to scroll through the list of parameters. If there are no active fault codes, the EIP
LCD will display NO CODE.
When a parameter is displayed, its label is displayed for 3 seconds, after which its value is automatically displayed.
Pressing OK button (C) while the value is displayed will advance to the next parameter and display its label.
When a parameter label is displayed and OK button (C) is pressed before 3 seconds, the parameter
’
s value will be
displayed.