215184
220
Revision A
1001438
B
A
D
C
Figure 7.36: Combine and Float Module
9.
On the left side of the feeder house, lift lever (A) on the
float module and push handle (B) on the combine to
engage locks (C) on both sides of the feeder house.
10. Push down on lever (A) so the slot in the lever engages the
handle and locks the handle in place.
11. If lock (C) does not fully engage the pin on the float
module, loosen bolts (D) and adjust lock. Retighten bolts.
1016561
A
B
C
Figure 7.37: Float Module Receptacle
12. Open the cover on receptacle (A) located on the left side of
the float module.
13. Press lock button (B) and pull handle (C) to the fully-open
position.
14. Clean the receptacle mating surfaces.
1001436
A
Figure 7.38: Combine Connectors
15. Remove hydraulic quick coupler (A) from the combine, and
clean the mating surfaces.