215184
189
Revision A
1017575
B
A
Figure 6.31: Right Side of Wide Configuration
4.
Install flighting slot plug (A) (MD #213084) in the flighting
slot from inside the auger. Secure with M6 hex head
bolts (B) (MD #252703) and tee nuts (MD #197263).
5.
Repeat above steps at the left side of the auger.
6.
Install additional fingers. A total of 30 fingers are
recommended for the Wide configuration. For instructions,
refer to
6.2.10 Installing Feed Auger Fingers, page 198
.
To convert from Medium configuration to Ultra Wide configuration, follow these steps:
1032277
B
D
A
C
D
C
Figure 6.32: Right Side of Medium Configuration
7.
Remove bolts (A) and access cover (B). Retain for
reassembly.
8.
Remove hardware from locations (C), and remove all
bolt-on flightings (D) from the feed auger.
NOTE:
Hardware on opposite side of auger indicated, but not
shown in illustration.
1017575
B
A
Figure 6.33: Right Side of Ultra Wide Configuration
9.
Install flighting slot plug (A) (MD #213084) in the flighting
slot from inside the auger. Secure with M6 hex head
bolts (B) (MD #252703) and tee nuts (MD #197263).
10. Repeat above steps at the left side of the auger.
11. Install additional fingers. A total of 30 fingers are
recommended for the Ultra Wide configuration. For
instructions, refer to