215184
315
Revision A
1025391
A
B
Figure 9.18: AHHC Sensor Assembly
2.
Follow these steps to adjust the low voltage limit:
a.
Extend guard angle fully; the header angle indicator
should be at
D
.
b.
Fully lower header on the ground; the float indicator
should be at
4
.
c.
Check the low voltage limit using the combine display
or voltmeter. For voltage limit chart, refer to Table
.
d.
Loosen sensor-mounting nuts (A).
e.
Rotate sensor (B) clockwise to increase low voltage
limit or counterclockwise to decrease it.
f.
Tighten sensor-mounting nuts (A).
3.
After making adjustments, recheck both the upper and
lower voltage limits to make sure they are within the
required range according to Table