Capter 2
Name and Function of Each Part (Outline)
Curve Tracer CS-3000 Series Instruction Manual
2-25
CAUTION
!
About the caution marks and the voltages that display in the panel and the
patch panel of the test fixture
Missing proper wireling and/or wrong connection may conduct wrong measurement. Also
these connections may cause of damage on DUT and/or malfunction of the unit.
Case: NOT connecting Collector output terminal and Emitter terminal and connecting Collector
sense terminal and Emitter sense terminal respectively;
It may cause for burn of SENSE RESISTER inside of the unit since the sense resister
connected to output of Collector output for Kelvin sensing and may be supplied exceeded
current specification.
2.11 Test adapter CS-508 (SMD CHIP type adapter, option)
Figure 2.24 shows the front side of test adapters CS-508 of this instrument and Figure 2.25 shows the
example of shape of SMD CHIP. The summary about part names and functions is presented in Table
2.20 of next page.
Test adapter CS-508 (SMD CHIP test adapter) is an option and can be attached to test fixture CS-302
with the screws for the fixation of both ends instead of the patch panel.
Figure 2.24
Test adapter CS-508
①
②
④
Figure 2.25 Example of shape of SMD CHIP
①-
A
①-
B
①-
C
③
⑤
Screws for the fixation
(
Test fixture
)
*
Attach in the following direction.
Left toward the applied part of
①
-A: ANODE
Right toward the applied part of
①
-A: CATHODE