Capter 3
Function Setting and Basic Operation
3-114
Curve Tracer CS-3000 Series Instruction Manual
3.11.7.2
LIMIT SWEEP submenu
Pressing F2 key allows LIMIT SWEEP submenu to appear.
Key/knob
Setting items
Function description
F1
FUNCTION
VERTICAL
LIMIT
F1 is used to select items below. The value is set by rotating
FUNCTION knob.
- OFF:
No restriction on vertical axis
- < setting value:
Sets SWEEP restriction on the vertical axis.
When any value equal to or smaller than the
setting value is obtained, SWEEP stops. Points
being swept are displayed.
- > setting value:
Set SWEEP restriction on the vertical axis. When
any value equal to or larger than the setting value
is obtained, SWEEP stops. Points being swept are
displayed.
F2
FUNCTION
HORIZONTAL
LIMIT
F2 is used to select items below. The value is set by rotating
FUNCTION knob.
- OFF:
No restriction on horizontal axis
- < setting value:
Sets SWEEP restriction on the horizontal axis.
When any value equal to or smaller than the
setting value is obtained, SWEEP stops. Points
being swept are displayed.
- > setting value:
Set SWEEP restriction on the horizontal axis.
When any value equal to or larger than the setting
value is obtained, SWEEP stops. Points being
swept are displayed.
F3
~
F6
(Not used)
F1
F2
F3
F4
F5
F6