MAP 0440: Short in 48 Volts DC Power Distribution
020 (continued)
– Check the frame supervisor green LED #2 for an OFF condition, indicating a short condition.
Is there an indication of a short condition?
Yes No
021
– Go to Step 017 on page 1-260.
022
– Go to Step 019 on page 1-260 to continue service.
023
Either no short condition was detected or the short condition was resolved.
– Go to “MAP 0570: End of Call” on page 1-357.
Chapter 1. Maintenance Analysis Procedures (MAPs)