MAP 0380: Power Distribution Unit (PDU)
MAP 0380: Power Distribution Unit (PDU)
The 48 V dc power system consists of the following components:
ac line cord
ac line filter
Main circuit breaker
Contactor
48 V Power chassis
Bulk dc power supplies
Busbars
48 V dc distribution cables
Miscellaneous cables.
The supervisor 12/24 V dc power system consists of the following components:
Supervisor 12 V dc power supply (S1)
Contactor main power switch 24 V dc power supply (S2)
PDU rear panel LED
Main power switch LED
Connector card
Supervisor harnesses
Miscellaneous cables.
Refer to the following two figures:
Figure 1-20 on page 1-226, for a view of the RS/6000 SP frame power diagram
Figure 1-21 on page 1-228, for a view of the ac wiring diagram for the RS/6000 SP power distribution
unit.
Chapter 1. Maintenance Analysis Procedures (MAPs)
1-225