MAP 0480: Open in 48 Volt DC Distribution
009 (continued)
– Check the 3-digit LEDs for the processor nodes to make sure they are all IPLing okay.
Do all processor nodes IPL okay?
Yes No
010
Processor nodes not IPLed.
– Go to “MAP 0100: Start of Service Call” on page 1-4 to continue service.
011
Processor nodes have IPLed okay.
Does this frame contain a switch assembly?
Yes No
012
Problem resolved.
– Go to “MAP 0570: End of Call” on page 1-357.
013
– Go to Step 014.
014
Frame contains switch assemblies.
– Go to Step 101 on page 1-350 of the “MAP 0540: Switch Function” on page 1-322 to verify fix.
Chapter 1. Maintenance Analysis Procedures (MAPs)
1-285
Summary of Contents for RS/6000 SP
Page 1: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Page 2: ......
Page 3: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Page 8: ...vi RS 6000 SP MAPs...
Page 10: ...viii RS 6000 SP MAPs...
Page 16: ...xiv RS 6000 SP MAPs...
Page 20: ...xviii RS 6000 SP MAPs...
Page 60: ...MAP 0130 Processor Node Figure 1 7 Thin Node High Level Diagram 1 40 RS 6000 SP MAPs...
Page 383: ......
Page 387: ......