![IBM RS/6000 SP Maintenance Information Download Page 191](http://html2.mh-extra.com/html/ibm/rs-6000-sp/rs-6000-sp_maintenance-information_3502216191.webp)
MAP 0300: 332 MHz SMP Node Power
019 (continued)
– Go to “MAP 0570: End of Call” on page 1-357.
020
– Go to Step 037 on page 1-172.
021
Is the power supplies yellow LED on or flashing?
Yes No
022
Verify the CB is On.
– Go to Step 030.
023
+48 V present.
Is the power supplies green power LED flashing?
Yes No
024
Is the power supplies green LED on steady?
Yes No
025
The LED is Off.
– Exchange the power supply.
026
– Go to “MAP 0570: End of Call” on page 1-357.
027
Switch the CB Off, then On.
Did the green LED light and the node IPL?
Yes No
028
– Go to MAP 0290: 332 MHz SMP Node Environment, Step 048 on page 1-165.
029
– Go to “MAP 0570: End of Call” on page 1-357.
030
(Step 030 continues)
Chapter 1. Maintenance Analysis Procedures (MAPs)
1-171