MAP 0330: POWER3 SMP Thin and Wide Node Environment
060 (continued)
Have memory parts been changed recently (since last successful IPL) in this processor node?
Yes No
061
Problem may be: base memory card, CPU card, I/O planar, or node supervisor control cable.
– Replace parts, one at a time, until problem is corrected.
Are you able to correct the problem?
Yes No
062
Call next level of support.
063
Problem resolved.
– Go to “MAP 0570: End of Call” on page 1-357.
064
– Check memory card and SIMM part numbers in
Diagnostic Information for Micro Channel Bus Systems
(SA38-0532) and
Adapters, Devices and Cable Information (SA38-0533) to ensure that they are com-
patible with the fastest Type 7013 machines.
– If necessary, call next level of support.
Chapter 1. Maintenance Analysis Procedures (MAPs)