MAP 0230: Wide Processor Node Control
011 (continued)
– Reoccurrence of intermittent fault has been detected.
– Treat this fault as a solid failure.
– Go to Step 024 on page 1-113.
012
– From the control workstation node front panel display:
Power-off processor node.
Power-on processor node.
Check 3-digit LEDs for LED sequence indicating IPL.
Do the 3-digit LEDs change?
Yes No
013
Node supervisor card not responding to commands.
– Go to “MAP 0110: Supervisor Subsystem” on page 1-10.
014
Processor node is IPLing.
Do 3-digit LEDs eventually indicate completion of IPL sequence (i.e. blank or “uuu”)?
Yes No
015
Processor node has problem IPLing.
Do 3-digit LEDs stop at constant 200?
Yes No
016
– Go to Step 008 on page 1-88 to continue service.
017
Problem with SECURE signal.
– Go to Step 024 on page 1-113 to continue service.
018
– From node front panel display, click on “TTY” button to open a TTY console.
– From the TTY console:
Select “Advanced Diagnostic Routines”
Select “System Verification”
Select “Base System”.
– Follow directions for the “Key Mode Switch Test”, setting the mode switch from the processor node‘s
front panel on the control workstation.
(Step 018 continues)
1-112
RS/6000 SP MAPs
Summary of Contents for RS/6000 SP
Page 1: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Page 2: ......
Page 3: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Page 8: ...vi RS 6000 SP MAPs...
Page 10: ...viii RS 6000 SP MAPs...
Page 16: ...xiv RS 6000 SP MAPs...
Page 20: ...xviii RS 6000 SP MAPs...
Page 60: ...MAP 0130 Processor Node Figure 1 7 Thin Node High Level Diagram 1 40 RS 6000 SP MAPs...
Page 383: ......
Page 387: ......