![IBM RS/6000 SP Maintenance Information Download Page 263](http://html2.mh-extra.com/html/ibm/rs-6000-sp/rs-6000-sp_maintenance-information_3502216263.webp)
MAP 0400: Supervisor Power 12 Volts DC Problem
044 (continued)
– Reinstall cover(s) over Power Distribution Unit section(s) panel.
– Reapply power to the frame, then check for LEDs lit on the frame supervisor card.
Are any LEDs lit on frame supervisor card?
Yes No
045
Problem not resolved.
– Go to Step 005 on page 1-238.
046
Problem resolved.
– Go to “MAP 0570: End of Call” on page 1-357.
047
Another short exists in the 12 V dc distribution.
– Go to Step 014 on page 1-239.
Chapter 1. Maintenance Analysis Procedures (MAPs)