MAP 0230: Wide Processor Node Control
003 (continued)
Was mode originally in SERVICE position as noted in previous step?
Yes No
004
– Customer may have tried to reset processor node in SECURE mode. Reset will only take
effect in NORMAL or SERVICE modes.
– From the control workstation, reset this processor node.
Does processor node reset?
Yes No
005
– Problem with reset.
– Go to Step 012 on page 1-112
006
– No problem found
– Inform customer that the processor node will not reset if the mode switch is in the SECURE
position.
– Go to “MAP 0570: End of Call” on page 1-357.
007
– From the control workstation, issue reset from this processor node.
Does the processor node reset?
Yes No
008
– Problem with reset.
– Go to Step 012 on page 1-112.
009
– Intermittent problem may be occurring.
– Record the following:
Node number
Date / Time fault reported
Type of fault reported.
– Check logs to see if this fault has been previously recorded.
Is this a recurring fault?
Yes No
010
– This is not a recurring failure.
– Go to “MAP 0570: End of Call” on page 1-357.
011
(Step 011 continues)
Chapter 1. Maintenance Analysis Procedures (MAPs)
1-111
Summary of Contents for RS/6000 SP
Page 1: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Page 2: ......
Page 3: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Page 8: ...vi RS 6000 SP MAPs...
Page 10: ...viii RS 6000 SP MAPs...
Page 16: ...xiv RS 6000 SP MAPs...
Page 20: ...xviii RS 6000 SP MAPs...
Page 60: ...MAP 0130 Processor Node Figure 1 7 Thin Node High Level Diagram 1 40 RS 6000 SP MAPs...
Page 383: ......
Page 387: ......