MAP 0460: Scalable Electrical Power Base Unit
Priority
Condition
Action
1
Main power switch LED is Off
-AND- SEPBU rear panel LED is Off
-AND- Frame Supervisor LEDs are Off.
Go to Step 002 on page 1-267.
2
Main power switch LED is On
-OR- SEPBU rear panel LED is On,
-BUT- all frame supervisor LEDs are Off.
Go to Step 032 on page 1-272.
3
Main power switch LED is Off
Go to Step 035 on page 1-272.
4
System monitor log reports “dc Power Loss” for
any power module(s).
Go to Step 051 on page 1-274.
5
Frame temperature is over 40° C.
Go to Step 081 on page 1-278.
6
Problem with 48 V dc power distribution to
processor node(s) or switch assemblies.
Go to “MAP 0480: Open in 48 V dc
Distribution” on page 1-283.