MAP 0280: 604 or 604e High Node Minimum Configuration
021 (continued)
Did the symptom change?
Yes No
022
– Call the next level of support.
023
– Check for loose cards, cables, and obvious problems. If you do not find a problem, return to Step
001 on page 1-146 and follow the instructions for the new symptom.
024
The system is working correctly with this configuration. One of the adapters that you removed is probably
defective.
– Set the circuit breakers to the Off (‘0’) position.
– Install one adapter, and connect any cables and devices that were attached to it.
– Set the circuit breakers to the On (‘1’) position.
– Start the diag boot from hdisk0 or net boot.
– If the Maintenance Menu is displayed, select System Boot, then Boot From List.
– Wait for one of the following conditions to occur:
The system stops with ‘c31’ displayed in the operator panel display.
The system stops with a flashing or solid ‘269’ displayed in the operator panel display.
The same three digit number is displayed in the operator panel display for longer than three minutes
except for the number ‘165’ which may display for up to ten minutes with no activity on the BUMP
console.
The number ‘888’ or ‘---’ is in the operator panel display.
Is ‘Diagnostic Operating Screen’ or ‘c31’ displayed in the operator panel display?
Yes No
025
– Go to Step 027.
026
– Repeat Step 024 until all of the adapters are installed.
– Go to “MAP 0570: End of Call” on page 1-357.
027
– Set the circuit breakers to the Off (‘0’) position.
– Starting with the last installed adapter, disconnect one attached device and cable.
– Set the circuit breakers to the On (‘1’) position.
– If the Maintenance Menu is displayed, select System Boot, then Boot From List.
– Wait for one of the following conditions to occur:
The system stops with ‘c31’ displayed in the operator panel display.
The system stops with a flashing or solid ‘269’ displayed in the operator panel display.
The same three digit number is displayed in the operator panel display for longer than three minutes
except for the number ‘165’ which may display for up to ten minutes with no activity on the BUMP
console.
(Step 027 continues)
1-152
RS/6000 SP MAPs
Summary of Contents for RS/6000 SP
Page 1: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...
Page 2: ......
Page 3: ...RS 6000 SP IBM Maintenance Information Volume 2 Maintenance Analysis Procedures GA22 7376 01...