8-26
745 Transformer Management Relay
GE Power Management
8.3 MODBUS MEMORY MAP
8 COMMUNICATIONS
8
10TH
HARMONIC
0360
Winding 1 Phase A 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0361
Winding 1 Phase B 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0362
Winding 1 Phase C 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0363
Winding 2 Phase A 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0364
Winding 2 Phase B 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0365
Winding 2 Phase C 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0366
Winding 3 Phase A 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0367
Winding 3 Phase B 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0368
Winding 3 Phase C 10th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0369
Reserved
↓
↓
↓
↓
↓
↓
↓
036F
Reserved
11TH
HARMONIC
0370
Winding 1 Phase A 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0371
Winding 1 Phase B 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0372
Winding 1 Phase C 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0373
Winding 2 Phase A 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0374
Winding 2 Phase B 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0375
Winding 2 Phase C 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0376
Winding 3 Phase A 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0377
Winding 3 Phase B 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0378
Winding 3 Phase C 11th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0379
Reserved
↓
↓
↓
↓
↓
↓
↓
037F
Reserved
12TH
HARMONIC
0380
Winding 1 Phase A 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0381
Winding 1 Phase B 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0382
Winding 1 Phase C 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0383
Winding 2 Phase A 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0384
Winding 2 Phase B 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0385
Winding 2 Phase C 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0386
Winding 3 Phase A 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0387
Winding 3 Phase B 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0388
Winding 3 Phase C 12th Harmonic Content
0.0 to 99.9
0.1
% ƒo
F2
---
0389
Reserved
↓
↓
↓
↓
↓
↓
↓
038F
Reserved
Table 8–6: 745 MEMORY MAP (Sheet 10 of 57)
GROUP
ADDR
(HEX)
DESCRIPTION
RANGE
STEP
VALUE
UNITS
FORMAT
CODE
FACTORY
DEFAULT
Summary of Contents for 745 TRANSFORMER MANAGEMENT RELAY
Page 30: ...2 8 745 Transformer Management Relay GE Power Management 2 3 SECURITY 2 GETTING STARTED 2 ...
Page 210: ...7 36 745 Transformer Management Relay GE Power Management 7 2 BLOCK DIAGRAMS 7 SCHEME LOGIC 7 ...
Page 322: ...9 12 745 Transformer Management Relay GE Power Management 9 3 USING 745PC 9 745 PC SOFTWARE 9 ...
Page 396: ...A 4 745 Transformer Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Page 400: ...C 2 745 Transformer Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Page 406: ...vi 745 Transformer Management Relay GE Power Management ...
Page 407: ...GE Power Management 745 Transformer Management Relay NOTES ...