Dual (Redundant)
Controller
Configuration
This section details the basic information needed to configure the settings of dual
VNM EC 200s for redundant operation. For information on how to set up a single controller,
see
Single VNM EC 200 Configuration
This section provides information on:
•
•
•
Configuring Dual EC 200s as the System Controller
•
Configuring VN‑Matrix Devices for Dual VNM EC 200 Operation
•
NOTE:
For additional configuration information, see
on page 19. Except for the IP Address, configure each VNM EC 200
identically.
Setup Overview
1.
Connect one VNM EC 200 to the control PC and change the default IP address (see
Configuring the Network Settings (Eth0)
2.
Use a network switch to connect the primary VN-Matrix network to the rear panel
LAN A Ethernet connector (eth
0
) of each VNM EC 200 (see
3.
Use an RJ-45 crossover cable to connect the VNM EC 200 LAN B (eth1) Ethernet
connectors together (see
page 8).
4.
Power on each VNM EC 200, all VN-Matrix devices present in the system, and all
necessary devices (see
5.
Connect a control PC to the VN-Matrix network and navigate to the Web-based user
interface of each VNM EC 200 (see
Accessing the Web‑based User Interface
6.
Configure the settings of each VNM EC 200 (see
7.
Configure the VNM EC 200 pair to act as the controller for the VN-Matrix system (see
Configuring Dual EC 200s as the System Controller
8.
Configure the devices within the VN-Matrix system (see
Devices for Dual VNM EC 200 Operation
9.
If necessary, update the license of each VNM EC 200 (see
10.
Power down each VNM EC 200 and all configured devices (see
on page 12). After a few seconds, power on each VNM EC 200 and all
necessary devices.