Configuring the Secondary EC 200 Time Settings
Use the following procedure to configure the time settings of the redundant secondary
VNM EC 200.
1.
Log in to the
redundant secondary
on page 11) and click the
Configuration
tab.
The
Configuration
page opens (see figure 160,
1
).
2
2
4
4
5
5
3
3
6
6
1
1
Figure 160.
Configuration Page — Secondary Controller Time Setup
2.
Under
Device
Properties
, click the
Time
link (
2
).
3.
Select the desired time zone from the
Set
timezone
drop-down list (
3
). Choose the
same time zone selected for the
redundant primary
VNM EC 200.
4.
In the
Clock
Syncronization
panel, check
Enable
Clock
Synchronization
(
4
). This syncs the time settings of this VNM EC 200 to the devices listed in the
Sources
field.
5.
Click
Add
(
5
) to open the IP address dialog box. Enter the IP address of the
redundant primary
VNM EC 200 and click
OK
to close the dialog.
6.
Click
Apply
Changes
to save the configuration (
6
).
VNM EC 200 • Dual (Redundant) Controller Configuration