analogOutputSetLevel
The
analogueOutputSetLevel
command sets the level of the audio channel on
VNS 104 devices. The command is sent to window 4, the VNS 104 audio channel.
NOTE:
This command uses zero-based window numbering. Channel numbers
0
to
3
refer to the top-left, top-right, bottom-left and bottom-right positions respectively.
Channel number 4 selects the audio channel.
Command line structure
set device
identifier
swdecoder window 4
analogOutputSetLevel
level
Available parameters and arguments for this command are:
Parameter
Argument
Description
identifier
Device
ID,
IP
address,
or
device
name
level
integer between
-70
and
12
For the following examples:
VNS 104:
Name =
104_Device1
, ID =
40001
, IP =
192.168.0.41
Example 1 - Set the audio level on a VNS 104 to a value of +6 using the device name.
set device
104_Device1
swdecoder window 4
analogOutputSetLevel
6
]
Example 2 - Set the audio level on a VNS 104 to a value of -36 using a device ID:
set device
40001
swdecoder window 4
analogOutputSetLevel
-36
]
connect
The
connect
command switches streams from a source device to a destination device.
This command manages the individual parameters required to configure a VN-Matrix
stream, including the provisioning of the VN-Matrix devices, to their required state.
Command line structure
connect
source:n destination:n
[
optional
parameters
]
Available parameters and arguments for this command are:
Parameter
Argument
Description
source:n
Device
ID,
IP
address
, or
Device
name
followed by an optional
channel number
:n
destination
Device
ID,
IP
address
, or
Device
name
followed by an optional
channel number
:n
Additional stream types (audio, data, whiteboard) can be specified as well as the network
transport protocol (TCP, UDP or multicast) using optional parameters. Unless otherwise
specified, the current global values as defined in the System Controller are used.
The channel designator
:n
provides support for channel-based devices such as the
VN Recorder and VNS 104.
If either the source or destination devices are a VNM Recorder or VNR 100, the connect
command is also used to select or create a directory for recording or to load an existing
directory for playback.
If the command and parameters are correctly entered and accepted by the controller the
return is:
"okay"