Alarm Type Reference Tables
Encoders
CLI Alarm
Alarm Description
Fault Description
Alarm Type
NOSRC
No Source
No input source is connected.
Critical, Reporting
BADSRCSYN
Bad Source Syncs
An input source is connected
but the sync timing is not
recognized
(unable to input
source due to bad sync
measurements).
Critical, Reporting
NOSDILOCK
No SDI Source Lock
An SDI source is connected
but the signal timing is not
recognized.
(An SDI source is present but the
PLL lock failed).
Critical, Reporting
NOSDIMODE
Unsupported SDI
Mode
The connected SDI source
mode not supported.
Critical, Reporting
NOMODE
Unsupported Mode
The connected source is not
supported; a user-mode must
be created.
Critical, Reporting
BADSRC
Bad Source
A source is connected and
syncs have been detected, but
it is not possible to make active
pixel measurements.
Critical, Reporting
PHASING
Analog Phasing Failure The analog pixel clock auto-
phasing process failed.
Warning, Reporting
HWNOVIDEO
Hardware Encoding
Error
The hardware is unable to
encode the input video.
Critical, Reporting
UNSUPAUDIOSRC
Unsupported Audio
Source
The digital audio source has a
bad or unsupported clock rate.
Critical, Reporting
BADAUDIOSRC
Bad Audio Source
The audio source is not valid
for the current video source.
Warning, Reporting
VIDEOOVERLOAD
Data Rate Overload
The system is not able to
process the source at the
current settings; increase the
compression.
(The compressed data rate is too
high, increase the compression).
Critical, Reporting
NWOVERLOAD
Network Overload
The network is dropping too
many packets.
Warning, Reporting
BADREVAUDIO
Bad Reverse Audio
The reverse audio channel
contains no data or has a large
number of dropouts.
Warning, Reporting
VNM EC 200 • Alarms
158
Summary of Contents for VNM EC 200
Page 6: ......