Removing controllers from the Sources list
1.
To remove a controller from the list, select a controller from the
Sources
list (see
2
on page 23).
2.
Click the
button (
2
in step 1 on the previous page) located below the
Sources
list to remove the selected IP address.
3.
When finished, click
Apply
Changes
located at the lower right corner of the Web page
(see
5
).
Enabling clock synchronization
1.
Add all of the controller IP addresses to the
Sources
list (see
Do not add
service (cluster) IP addresses.
2.
Select (checked) the
Enable
Clock
Synchronization
check box (see
2
on page 23 and below).
3.
Click
Apply
Changes
, located at the lower right corner of the Web page, to save the
setting.
4.
Repeat this procedure for each controller device listed in the
Sources
list.
Disabling clock synchronization
1.
Deselect the
Enable
Clock
Synchronization
check box (unchecked).
2.
Click
Apply
Changes
, located at the lower right corner of the Web page, to save the
setting.
Clock Settings Panel
,
3
) is used to set the local time and date on the controller that is
logged into.
NOTES:
•
Do not alter these fields if logged into the cluster IP address.
•
If
Enable
Clock
Synchronization
is selected in the
Clock
Synchronization
panel, the values in this panel are dimmed.
•
Set time
— Enter the local time into this field or use the drop-down list button located
at the right side of this field to select the desired time.
The time is entered as follows.
•
Use the
HH:MM:SS
(
hours:minutes:seconds
) format based on the 24-hour
clock. For example,
08:25:00
or
20:35:10
.
•
Set date
— Enter the current date into this field or use the calendar button located at
the right side of this field to open a calendar and select the desired date.
The date is entered as follows.
•
Use the
MM/DD/YYYY
(
month/day/year
) format. For example,
05/14/2012
.