XRT86VL38
PRELIMINARY
xr
OCTAL T1/E1/J1 FRAMER/LIU COMBO
REV. P1.0.6
249
4
SA6_1010_ENB
R/W
0
Change in Debounced Sa6 = 1010 Interrupt Enable
This READ/WRITE bit field enables or disables the “Change in
Debounced Sa6=1010” interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1.
Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1010 pattern.
2.
Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1010 pattern.
0 = Setting this bit to ‘0’ will disable the “Change in Debounced
Sa6=1010” interrupt within the Receive E1 Framer Block
1 = Setting this bit to ‘1’ will enable the “Change in Debounced
Sa6=1010” interrupt within the Receive E1 Framer Block
3
SA6_1000_ENB
R/W
0
Change in Debounced Sa6 = 1000 Interrupt Enable
This READ/WRITE bit field enables or disables the “Change in
Debounced Sa6=1000” interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1.
Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1000 pattern.
2.
Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1000 pattern.
0 = Setting this bit to ‘0’ will disable the “Change in Debounced
Sa6=1000” interrupt within the Receive E1 Framer Block
1 = Setting this bit to ‘1’ will enable the “Change in Debounced
Sa6=1000” interrupt within the Receive E1 Framer Block
2
SA6_001x_ENB
R/W
0
Change in Debounced Sa6 = 001x Interrupt Enable
This READ/WRITE bit field enables or disables the “Change in
Debounced Sa6=001x” interrupt within the E1 Receive Framer,
where x is don’t care.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1.
Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 001x pattern.
2.
Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 001x pattern.
0 = Setting this bit to ‘0’ will disable the “Change in Debounced
Sa6=001x” interrupt within the Receive E1 Framer Block
1 = Setting this bit to ‘1’ will enable the “Change in Debounced
Sa6=001x” interrupt within the Receive E1 Framer Block
T
ABLE
140: R
ECEIVE
SA I
NTERRUPT
E
NABLE
R
EGISTER
(RSAIER)
R
EGISTER
540 R
ECEIVE
SA I
NTERRUPT
E
NABLE
R
EGISTER
(RSAIER) H
EX
A
DDRESS
: 0
X
nB0D
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O
PERATION