xr
PRELIMINARY
XRT86VL38
REV. P1.0.6
OCTAL T1/E1/J1 FRAMER/LIU COMBO
160
The following table demonstrates the conditions on the receive side which trigger the Automatic Sa,
and A bit transmission when TSACR1 bits are enabled.
1
NOP_LOSLFA_ENB
R/W
0
No power and LOS/LFA automatic transmission
This READ/WRITE bit-field enables the auto Sa-bit transmission
upon detecting the following two conditions:
1.
Upon Loss of Power and Loss of Signal (LOS) or
2.
Upon Loss of Power and Loss of frame alignment (LFA)
When the E1 framer detects any one of the above two conditions,
E1 framer will transmit the Alarm bit (A bit) as ‘1’, Sa5 bit as ‘1’, Sa6
bit as ‘1000’ pattern.
See Table 69 for the transmit Sa5, Sa6, and A bit format upon
detecting loss of power and LOS/LFA conditions.
0
LOS_2_ENB
R/W
0
LOS 3 automatic transmission
This READ/WRITE bit-field enables the auto Sa-bit transmission
upon detecting Loss of Signal (LOS) condition.
Upon detecting Loss of Signal condition, E1 framer will transmit the
Sa5 and Sa6 bit as an Auxiliary (10101010...) pattern
See Table 69 for the transmit Sa5, Sa6, and A bit format upon
detecting LOS condition.
T
ABLE
69: C
ONDITIONS
ON
R
ECEIVE
SIDE
W
HEN
TSACR1
BITS
A
RE
ENABLED
C
ONDITIONS
A
CTIONS
-
SENDING
PATTERN
C
OMMENTS
A
S
A
5
S
A
6
LOSLFA_1_ENB: Loss of signal or Loss of
frame alignment
X
1
0000
LOS/LFA at TE (FC2)
LOS_1_ENB: Loss of signal
1
1
1110
LOS (FC3)
LOSLFA_2_ENB: LOS or LFA
1
0
0000
LOS/LFA (FCL)
LOSLFA_3_ENB: LOS or LFA
0
1
1100
LOS/LFA (FC4)
LOSLFA_4_ENB: LOS or LFA
0
1
1110
LOS/LFA (FC3&FC4)
NOP_ENB: Loss of power
0
1
1000
Loss of power at NT1
NOP_LOSLFA_ENB: Loss of power and LOS
or LFA
1
1
1000
Loss of power and LOS/LFA
LOS_2_ENB: LOS
AUXP pattern
LOS (FC1). Transmit AUXP pattern
T
ABLE
68: T
RANSMIT
Sa A
UTO
C
ONTROL
R
EGISTER
1 - E1 M
ODE
O
NLY
R
EGISTER
39 T
RANSMIT
S
A
A
UTO
C
ONTROL
R
EGISTER
1 (TSACR1) 0
XN
131
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O
PERATION