Create RAID Virtual Disk (Manual Physical Disk Select)
This command creates a new disk group and virtual disk, and enables you to
specify the physical disks for the virtual disk.
NOTE:
You cannot use mixed physical disk types in the same disk group and virtual
disk. This command fails if you specify different types of physical disks for the RAID
virtual disk.
Syntax
create virtualDisk physicalDisks
(enclosureID1,slotID1 enclosureID2,slotID2...
enclosureIDn,slotIDn)
[volumeGroupUserLabel=[diskGroupName]]
usageHint
The settings for both the
cacheReadPrefetch
parameter and the
segmentSize
parameter should be the
default values. The default values are
based on the typical I/O usage pattern of
the application that is using the virtual
disk. Valid values are
fileSystem
,
dataBase
, or
multiMedia
.
dssPreAllocate
The setting to make sure that reserve
capacity is allocated for future segment
size increases. The default value is
TRUE
.
securityType
The setting to specify the security level
when creating the disk groups and all
associated virtual disks.
•
none
—The disk group and virtual disks
are not secure.
•
capable
—The disk group and virtual
disks are capable of having security set,
but security has not been enabled.
•
enabled
—The disk group and virtual
disks have security enabled.
For information about securityType, see
"Security Type" on page 127.
Parameter
Description
book.book Page 137 Friday, March 4, 2011 10:45 AM
Summary of Contents for PowerVault MD3200 Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 42: ...42 About the Script Commands ...
Page 263: ...Script Commands 263 ...
Page 269: ...268 Sample Script Files ...
Page 271: ...270 CLI Command Updates ...
Page 279: ...Index 278 ...