Script Commands
Start Configuration Database Diagnostic
This command starts a diagnostic test to validate the configuration database
in the controller firmware.
Syntax
Start storageArray configDbDiagnostic
Parameters
None.
Notes
Upon completion of the diagnostic test, the controller firmware returns one
of these results:
•
Diagnosis completed without errors. No ZIP file
created.
•
Diagnosis completed with errors. Refer to the ZIP
file created at:
...\Install_dir\data\FirmwareUpgradeReports\times
tamp_buildNo.zip
If the diagnostic test detects an inconsistency in the configuration database,
the controller firmware performs these actions:
• Returns a description of the inconsistency
• Saves a ZIP file containing raw binary data
The controller firmware saves the ZIP file to this location:
...\Install_dir\data\FirmwareUpgradeReports\timestamp_buildNo.zip
The binary data can be used to help determine the cause of the problem, or
the file containing the binary data can be sent to a Customer and Technical
Support representative.
To stop the database configuration diagnostic test, use the
stop
storageArray configDbDiagnostic
command.