220
Script Commands
cacheWithoutBatteryEnabled
The setting to turn on or turn off caching
without batteries. To turn on caching without
batteries, set this parameter to
TRUE
. To turn
off caching without batteries, set this
parameter to
FALSE
.
mediaScanEnabled
The setting to turn on or turn off media scan
for the virtual disk. To turn on media scan, set
this parameter to
TRUE
. To turn off media
scan, set this parameter to
FALSE
. (If media
scan is disabled at the storage array level, this
parameter has no effect.)
mirrorCacheEnabled
The setting to turn on or turn off the mirror
cache. To turn on the mirror cache, set this
parameter to
TRUE
. To turn off the mirror
cache, set this parameter to
FALSE
.
modificationPriority
The priority for virtual disk modifications
while the storage array is operational. Valid
values are
highest
,
high
,
medium
,
low
, or
lowest
.
owner
The RAID controller module that owns the
virtual disk. Valid RAID controller module
identifiers are 0 or 1, where, 0 is the RAID
controller module in slot 0, and 1 is the RAID
controller module in slot 1. Use this parameter
only if you want to change the virtual disk
owner.
readCacheEnabled
The setting to turn on or turn off the read
cache. To turn on the read cache, set this
parameter to
TRUE
. To turn off the read
cache, set this parameter to
FALSE
.
writeCacheEnabled
The setting to turn on or turn off the write
cache. To turn on the write cache, set this
parameter to
TRUE
. To turn off the write
cache, set this parameter to
FALSE
.
Parameter
Description
book.book Page 220 Friday, March 4, 2011 10:45 AM