Script Commands
161
Parameters
Download Storage Array Firmware/NVSRAM
This command downloads firmware and, optionally, NVSRAM values for the
RAID controller module in the storage array. If you want to download only
NVSRAM values, use the
downLoad storageArray NVSRAM
command.
Syntax
download storageArray firmware [, NVSRAM ]
file="
filename
" [, "
NVSRAM-filename
"]
[downgrade=(TRUE | FALSE)]
[activateNow=(TRUE | FALSE)]
Parameters
Parameter
Description
physicalDisk
Physical disk to which to download the
firmware image. Specify the enclosure ID
and slot ID for the physical disk.
Enclosure ID values are 0 to 99. Slot ID
values are 0 to 31. You must put brackets
([ ]) around the enclosure ID value and
slot ID value.
filename
File path and file name of the file that
contains the firmware image. You must
put quotation marks (" ") around the
firmware image file path and file name.
Parameter
Description
NVSRAM
Specifies that you want to download a file
with NVSRAM values when you
download a firmware file. You must not
put brackets around this parameter.
Include a comma after the term
firmware
.
file
File path and name of the file that contains
the firmware. Valid file names must end
with a
.dlp
extension. You must put
quotation marks (" ") around the file name.
book.book Page 161 Friday, March 4, 2011 10:45 AM
Summary of Contents for PowerVault MD3200 Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 42: ...42 About the Script Commands ...
Page 263: ...Script Commands 263 ...
Page 269: ...268 Sample Script Files ...
Page 271: ...270 CLI Command Updates ...
Page 279: ...Index 278 ...