146
Script Commands
NOTE:
You can use any combination of alphanumeric characters, hyphens, and
underscores for the names. Command names can have a maximum of 30
characters. If you exceed the maximum character limit, replace square brackets
([ ]) with angle brackets (< >) to overcome this limitation.
NOTE:
One technique for naming the snapshot virtual disk and the repository
virtual disk is to add a hyphenated suffix to the original name of the source virtual
disk. The suffix distinguishes between the snapshot virtual disk and the repository
virtual disk. For example, if you have a source virtual disk with a name of
Engineering Data, the snapshot virtual disk can have a name of Engineering Data-
S1, and the repository virtual disk can have a name of Engineering Data-R1.
NOTE:
If you do not choose a name for the either the snapshot virtual disk or
repository virtual disk, the RAID controller modules create a default name using the
source virtual disk name. For example, if the source virtual disk name is aaa and
does not have a snapshot virtual disk, the default snapshot virtual disk name is
aaa – 1. If the source virtual disk already has
n
– 1 number of snapshot virtual disks,
the default name is aaa –
n
. If the source virtual disk name is aaa and the source
virtual disk does not have a repository virtual disk, the default repository virtual disk
name is aaa – R1. If the source virtual disk already has
n
– 1 number of repository
virtual disks, the default name is aaa – R
n
.
repositoryPercentOfSource
The size of the repository virtual disk as a
percentage of the source virtual disk. Use
integer values. For example, a value of 40
means 40 percent. The default value is 20.
repositoryUserLabel
The name to give to the repository virtual
disk. You must put quotation marks (" ")
around the repository virtual disk name.
repositoryFullPolicy
Specifies how snapshot processing
continues if the repository is full. You can
choose to fail writes to the source virtual
disk (
failSourceWrites
) or fail the
snapshot virtual disk (
failSnapShot
). The
default value is
failSnapShot
.
Parameter
Description
book.book Page 146 Friday, March 4, 2011 10:45 AM
Summary of Contents for PowerVault MD3200 Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 42: ...42 About the Script Commands ...
Page 263: ...Script Commands 263 ...
Page 269: ...268 Sample Script Files ...
Page 271: ...270 CLI Command Updates ...
Page 279: ...Index 278 ...