200
Script Commands
Set RAID Controller Module
This command defines the attributes for the RAID controller modules.
Syntax
set controller [(0 | 1)]
availability=(online | offline | serviceMode) |
ethernetPort [(1 | 2)]=ethernetPortOptions |
globalNVSRAMByte [nvsramOffset]=
(nvsramByteSetting |
nvsramBitSetting) |
hostNVSRAMByte [hostType, nvsramOffset]=
(nvsramByteSetting |
nvsramBitSetting) |
IPv4GatewayIP=ipAddress |
IPv6RouterAddress=ipv6Address |
iscsiHostPort [(1 | 2 | 3 | 4)]=
iscsiHostPortOptions
rloginEnabled=(TRUE | FALSE) |
serviceAllowedIndicator=(on | off)
Parameters
Parameter
Description
controller
The RAID controller module for which you want to
define properties. Valid identifiers for the RAID
controller module are 0 or 1, where, 0 is the RAID
controller module in slot 0, and 1 is the RAID
controller module in slot 1. Enclose the identifier
for the RAID controller module in square brackets
([ ]). If you do not specify a RAID controller
module, the firmware for the RAID controller
module returns a syntax error.
availability
The mode for the RAID controller module, which
you can set to
online
,
offline
, or
serviceMode
(service).
book.book Page 200 Friday, March 4, 2011 10:45 AM
Summary of Contents for PowerVault MD3200 Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 42: ...42 About the Script Commands ...
Page 263: ...Script Commands 263 ...
Page 269: ...268 Sample Script Files ...
Page 271: ...270 CLI Command Updates ...
Page 279: ...Index 278 ...