Script Commands
231
NOTE:
When all firmware downloads have successfully completed, this command
returns a
Successful
status. If any firmware downloads fail, this command shows
the firmware download status of each targeted physical disk. This command returns
the status values shown in the following table.
Show RAID Controller Module
For each RAID controller module in a storage array, this command returns the
following information:
• Status (Online, Offline)
• Current firmware and NVSRAM configuration
• Pending firmware and NVSRAM configuration configurations (if any)
• Board ID
• Product ID
• Product revision
• Serial number
• Date of manufacture
• Date and time to which the RAID controller module is set
• Associated virtual disks (including preferred owner)
• Ethernet port
• Physical disk interface
Syntax
show (allControllers | controller [(0 | 1)])
[summary]
Status
Definition
Successful
Downloads completed without errors.
Not Attempted
Downloads did not start.
Partial Download
Downloads are in progress.
Failed
Downloads completed with errors.
book.book Page 231 Friday, March 4, 2011 10:45 AM
Summary of Contents for PowerVault MD3200 Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 42: ...42 About the Script Commands ...
Page 263: ...Script Commands 263 ...
Page 269: ...268 Sample Script Files ...
Page 271: ...270 CLI Command Updates ...
Page 279: ...Index 278 ...