118
Script Commands
Autoconfigure Storage Array Hot Spares
This command automatically defines and configures the hot spares in a
storage array. You can run this command at any time. This command provides
the best hot spare coverage for a storage array.
Syntax
autoConfigure storageArray hotSpares
Parameters
None.
NOTE:
When you run the autoconfigure storageArray hotSpares command, the
RAID controller module firmware determines the number of hot spares to create
based on the total number and type of physical disks in the storage array.
Check Virtual Disk Consistency
This command checks a virtual disk for consistency and media errors, and
writes the results of the check to a file.
Syntax
check virtualDisk [virtualDiskName]
consistency [consistencyErrorFile=filename]
[mediaErrorFile=filename]
[priority=(highest | high | medium | low |
lowest)]
[startingLBA=LBAvalue] [endingLBA=LBAvalue]
[verbose=(TRUE | FALSE)]