Script Commands
215
Parameters
NOTE:
You can set the learn cycle to occur only once during a seven-day period.
The time parameter selects a specific time that you want to run the learn cycle. If a
value is not entered, the command uses a default value of 00:00 (midnight). If the
day and time specified are in the past, the next learn cycle takes place on the next
possible day specified.
Set Storage Array Redundancy Mode
This command sets the redundancy mode of the storage array to either
simplex or duplex.
Syntax
set storageArray redundancyMode=(simplex | duplex)
Parameter
Parameter
Description
daysToNextLearnCycle
Valid values are 0 through 7, where, 0 is immediately
and 7 is in seven days. The
daysToNextLearnCycle
parameter takes place up to seven days after the next
scheduled learn cycle.
day
Valid values for the day parameter include the days of
the week. Setting the day causes the next learn cycle
to be scheduled on the specified day, after the
currently scheduled learn cycle.
time
The time in 24-hour format; for example 8:00 a.m. is
entered as 08:00. Nine o’clock p.m. is entered as
21:00, and 9:30 p.m. is entered as 21:30.
Parameter
Description
redundancyMode
Use
simplex
mode when you have a single RAID
controller module. Use
duplex
mode when you have two
RAID controller modules
book.book Page 215 Friday, March 4, 2011 10:45 AM