Parameter
Description
Range
Default
received within the EAP rate time interval to
trigger an alarm.
eap-rate-time-interval
Time, in seconds, during which the
configured number of EAP handshakes must
be received to trigger an alarm.
1-120
seconds
3 seconds
fata-jack-quiet-time
Time to wait, in seconds, after detecting a
FATA-Jack attack after which the check can
be resumed.
60-360000
seconds
900
seconds
invalid-address-combination-
quiet-time
Time to wait, in seconds, after detecting an
invalid address combination after which the
check can be resumed.
60-360000
seconds
900
seconds
malformed-association-request-
quiet-time
Time to wait, in seconds, after detecting a
malformed association request after which
the check can be resumed.
60-360000
seconds
900
seconds
malformed-auth-frame-quiet-time
Time to wait, in seconds, after detecting a
malformed authentication frame after which
the check can be resumed.
60-360000
seconds
900
seconds
malformed-htie-quiet-time
Time to wait, in seconds, after detecting a
malformed HT IE after which the check can
be resumed.
60-360000
seconds
900
seconds
malformed-large-duration-quiet-
time
Time to wait, in seconds, after detecting a
large duration for a frame after which the
check can be resumed.
60-360000
seconds
900
seconds
no
Negates any configured parameter.
—
—
omerta-quiet-time
Time to wait, in seconds, after detecting an
Omerta attack after which the check can be
resumed.
60-360000
seconds
900
seconds
omerta-threshold
The Disassociation packets received by a
station as a percentage of the number of
data packets sent, in an interval of 10
seconds.
1-100
10%
overflow-eapol-key-quiet-time
Time to wait, in seconds, after detecting a
overflow EAPOL key request after which the
check can be resumed.
60-360000
seconds
900
seconds
overflow-ie-quiet-time
Time to wait, in seconds, after detecting a
overflow IE after which the check can be
resumed.
60-360000
seconds
900
seconds
power-save-dos-min-frames
The minimum number of Power
Management OFF packets that are required
to be seen from a station, in intervals of 10
second, in order for the Power Save DoS
check to be done.
1-1000
120
power-save-dos-quiet-time
Time to wait, in seconds, after detecting a
Power Save DoS attack after which the
60-360000
seconds
900
seconds
Dell PowerConnect W-Series ArubaOS 6.2 |
Reference Guide
ids dos-profile | 285
Summary of Contents for PowerConnect W-7200 Series
Page 1: ...Dell PowerConnect W Series ArubaOS 6 2 Command Line Interface Reference Guide ...
Page 38: ...38 aaa authentication server windows DellPowerConnect W Series ArubaOS 6 2 Reference Guide ...
Page 319: ...DellPowerConnect W Series ArubaOS 6 2 Reference Guide interface loopback 319 ...
Page 346: ...346 ipv6 mld DellPowerConnect W Series ArubaOS 6 2 Reference Guide ...
Page 387: ...DellPowerConnect W Series ArubaOS 6 2 Reference Guide ip radius 387 ...
Page 995: ...DellPowerConnect W Series ArubaOS 6 2 Reference Guide show firewall 995 ...
Page 1529: ...DellPowerConnect W Series ArubaOS 6 2 Reference Guide wms client 1529 ...
Page 1536: ...0510956 01 March 2013 1536 ...