state
- Specify that the port is a VLAN trunk port or not.
enable
- Specify that the port is a VLAN trunk port.
disable
- Specify that the port is not a VLAN trunk port.
Restrictions
Only Administrators can issue this command.
Example
To configure VLAN trunk ports:
DGS-3000-26TC:admin#config vlan_trunk ports 1-5 state enable
Command: config vlan_trunk ports 1-5 state enable
Success.
DGS-3000-26TC:admin#
Port 6 is LA-1 member port; port 7 is LA-2 master port:
DGS-3000-26TC:admin#config vlan_trunk ports 6-7 state enable
Command: config vlan_trunk ports 6-7 state enable
Warning: Port 6 is a Link Aggregation member port, VLAN trunk is not enabled on
port 6.
Success.
DGS-3000-26TC:admin#config vlan_trunk ports 7 state disable
Command: config vlan_trunk ports 7 state disable
Success.
DGS-3000-26TC:admin#config vlan_trunk ports 6-7 state disable
Command: config vlan_trunk ports 6-7 state disable
Warning: Port 6 is a Link Aggregation member port, VLAN trunk is not enabled on
port 6.
Success.
DGS-3000-26TC:admin#
Port 6 is LA-1 member port; port 7 is LA-1 master port:
DGS-3000-26TC:admin#config vlan_trunk ports 6-7 state enable
Command: config vlan_trunk ports 6-7 state enable
Success.
DGS-3000-26TC:admin#
Port 6, 7 have the same VLAN configuration before enabling VLAN trunk.