DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
808
Format
config syslog host [<index> | all] {severity [emergency | alert | critical | error | warning |
notice | informational | debug| <level 0-7>] | facility [local0 | local1 | local2 | local3 | local4 |
local5 | local6 | local7] | udp_port <udp_port_number> | ipaddress [<ipaddr> | <ipv6addr>] |
state [enable | disable]}(1)
Parameters
<index>
- Enter the host index value here.
all
- Specify that all the host indexes will be used.
severity
- Specify the severity level.
emergency
- Severity level 0.
alert
- Severity level 1.
critical
- Severity level 2.
error
- Severity level 3.
warning
- Severity level 4.
notice
- Severity level 5.
informational
- Severity level 6.
debug
- Severity level 7.
<level 0-7>
- Enter the severity level value here. This value must be between 0 and 7.
facility
- Some of the operating system daemons and processes have been assigned Facility
values. Processes and daemons that have not been explicitly assigned a Facility may use any
of the "local use" facilities or they may use the "user-level" Facility. Those Facilities that have
been designated are shown below. This facility setting will be put in the syslog packet when it
is sent to a specific syslog server.
local0
- Specify that the user-defined facility will be set to local 0.
local1
- Specify that the user-defined facility will be set to local 1.
local2
- Specify that the user-defined facility will be set to local 2.
local3
- Specify that the user-defined facility will be set to local 3.
local4
- Specify that the user-defined facility will be set to local 4.
local5
- Specify that the user-defined facility will be set to local 5.
local6
- Specify that the user-defined facility will be set to local 6.
local7
- Specify that the user-defined facility will be set to local 7.
udp_port
- Specify the UDP port number.
<udp_port_number>
- Enter the UDP port number used here.
ipaddress
- Specify IP address for the host.
<ipaddr>
- Enter the IP address used for the configuration here.
<ipv6addr>
- Enter the IPv6 address used for the configuration here.
state
- The syslog protocol is used for the transmission of event notification messages across
networks to a host. The option enables or disables the host to receive such messages.
enable
- Specify that the host to receive such messages will be enabled.
disable
- Specify that the host to receive such messages will be disabled.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure the syslog host configuration:
Summary of Contents for DGS-3000 series