DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
312
DGS-3000-26TC:admin#config ddm log enable
Command: config ddm log enable
Success.
DGS-3000-26TC:admin#
To configure DDM trap state to enable:
DGS-3000-26TC:admin#config ddm trap enable
Command: config ddm trap enable
Success.
DGS-3000-26TC:admin#
config ddm ports
25-2
Description
This command is used to configure the DDM settings of the specified ports.
Format
config ddm ports [<portlist> | all] [[temperature_threshold {high_alarm <degrees> |
low_alarm <degrees> | high_warning<degrees> | low_warning <degrees>}(1) |
voltage_threshold {high_alarm <voltage> | low_alarm<voltage> | high_warning<voltage> |
low_warning<voltage>}(1) | bias_current_threshold {high_alarm <milliampere> | low_alarm
<milliampere> | high_warning <milliampere> | low_warning<milliampere>}(1) |
tx_power_threshold {high_alarm <mw_or_dbm> | low_alarm <mw_or_dbm> | high_warning
<mw_or_dbm> | low_warning <mw_or_dbm>}(1) | rx_power_threshold {high_alarm
<mw_or_dbm> | low_alarm <mw_or_dbm> | high_warning <mw_or_dbm> | low_warning
<mw_or_dbm>}(1)] | {state [enable | disable] | shutdown [alarm | warning | none]}(1) |
reload_threshold]
Parameters
<portlist>
- Enter the range of ports to be configured here.
all
- Specify that all the optic ports’ operating parameters will be configured.
temperature_threshold
- Specify the threshold of the optic module’s temperature in centigrade.
At least one parameter shall be specified for this threshold.
high_alarm
-
Specify the high threshold value for the temperature alarm.When the operating
parameter rises above this value, the action associated with the alarm is taken.
<degrees>
- Enter the high threshold alarm value used here.
low_alarm
- Specify the low threshold value for the temperature alarm.When the operating
parameter falls below this value, the action associated with the alarm is taken.
<degrees>
- Enter the low threshold alarm value used here.
high_warning
- Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<degrees>
- Enter the high threshold warning value here.
low_warning
- Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<degrees>
- Enter the low threshold warning value here.
voltage_threshold
- Specify the threshold of optic module’s voltage.