DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
528
DGS-3000-26TC:admin#config mac_based_access_control ports 1-8 aging_time
infinite block_time 120
Command: config mac_based_access_control ports 1-8 aging_time infinite
block_time 120
Success.
DGS-3000-26TC:admin#
create mac_based_access_control
49-8
Description
This command is used to assign a static 802.1Q VLAN as a MAC-based Access Control guest
VLAN.
Format
create mac_based_access_control [guest_vlan <vlan_name 32> | guest_vlanid <vlanid 1-
4094>]
Parameters
guest_vlan
- Specify MAC-based Access Control guest VLAN by name, it must be a static 1Q
VLAN.
<vlan_name 32>
- Enter the VLAN name here. This name can be up to 32 characters long.
guest_vlanid
- Specify MAC-based Access Control guest VLAN by VID, it must be a static 1Q
VLAN.
<vlanid 1-4094>
- Enter the VLAN ID here. This value must be between 1 and 4094.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To create a MAC-based Access Control guest VLAN:
DGS-3000-26TC:admin#create mac_based_access_control guest_vlan VLAN8
Command: create mac_based_access_control guest_vlan VLAN8
Success.
DGS-3000-26TC:admin#
delete mac_based_access_control
49-9
Description
This command is used to remove a MAC-based Access Control guest VLAN.
Summary of Contents for DGS-3000 series