DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
764
Example
To show SNMP v6 host:
DGS-3000-26TC:admin#show snmp v6host
Command: show snmp v6host
SNMP Host Table
------------------------------------------------------------------
Host IPv6 Address : 3FFE::3
SNMP Version : V3 na/np
Community Name/SNMPv3 User Name : initial
Host IPv6 Address : 3FFE::2
SNMP Version : V2c
Community Name/SNMPv3 User Name : private
Host IPv6 Address : 3FFE::1
SNMP Version : V1
Community Name/SNMPv3 User Name : public
Host IPv6 Address : 3FFE::3
SNMP Version : V3 a/np
Community Name/SNMPv3 User Name : user123
Host IPv6 Address : 3FFE::3
SNMP Version : V3 a/ p
Community Name/SNMPv3 User Name : user234
Total Entries: 5
DGS-3000-26TC:admin#
config snmp engineID
78-21
Description
This command is used to configure a identifier for the SNMP engine on the Switch.
Format
config snmp engineID <snmp_engineID 10-64>
Parameters
<snmp_engineID 10-64>
- Enter the SNMP engine ID here. It is octet string type. It accepts the
hex number directly.This value must be between 10 and 64.
Restrictions
Only Administrators can issue this command.